OSE-C 2324
VITECTOR Measuring Tools & Sensors Surface Mounting, 24 V AC/DC, 2, 3-Wire, , Safety Cat. 3 PL d (EN 13849-1), Relay NCC, , Stop Output (NCC) & Reverse Contact (NOC) Available 0
Type de boîtier | Surface Mounting |
Type d'entrée de barre palpeuse | 3-Wire |
Sorties | Relay NCC |
Housing Type | Stop Output (NCC) & Reverse Contact (NOC) |
Tension d'alimentation | 24 V AC/DC |
Température de fonctionnement | -20 °C to +55 °C (-4 °F to 131 °F) |
Poids | 0.36 kg |
Matière du boîtier | Polycarbonate |
Indice de protection | IP65 |
Dimensions du boîtier | 130x94x60 mm (5.11x3.7x2.36") |
Consommation d'énergie | 7 VA |
Facteur de marche | 100% |
Nombre d'entrées de barre palpeuse optique | 2 |
Propriétés de sécurité | Safety Cat. 3 PL d (EN 13849-1) |
MTTFd | 44 years |
Taux de couverture des tests de diagnostic | 88 % |
Housing Type | NCC Relay |
Matière du contact | Hard Silver, AgNi |
Housing Type | 250 V AC/DC |
Housing Type | 4 A |
Housing Type | 4 A |
Housing Type | 1000 VA |
Housing Type | 10 x 10^6 operating cycles |
Housing Type | 4 A slow acting (not part of the unit) |
Housing Type | Relay NOC |
Matière du contact | Hard Silver, AgNi |
Housing Type | 250 V AC / 24 V DC |
Housing Type | 6 A |
Housing Type | 6 A |
Housing Type | AC15: 230 V / 2 A; DC13: 24 V / 3 A |
Housing Type | 20 x 10^6 operating cycles |
Housing Type | 6 A slow blowing (not part of unit) |
Housing Type | Relay NCC |
Matière du contact | Hard Silver, AgNi |
Housing Type | 250 V AC / 24 V DC |
Housing Type | 6 A |
Housing Type | 6 A |
Housing Type | AC15: 230 V / 2 A; DC13: 24 V / 3 A |
Housing Type | 10 x 10^6 operating cycles |
Housing Type | 6 A slow blowing (not part of unit) |
Unit of Measure | Pièce |
Cycle de vie des produits | Established |

All dimension in [inch] mm. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.
© CEDES AG., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.